Unless otherwise specified, the standard range of atmospheric conditions for making measurements
Tests are as follows:
Ambient temperatures: 5 to 35°C
Relative humidity: 45 to 85%
Air pressure: 85 to 106kPa
If there is any doubt about the results, measurements shall be made within the following limits
Ambient temperatures: 20±, 1°C
Relative humidity: 60 to 70%
Air pressure: 86 to 106kPa
Operating temperature: -25 to 60°C
Humidity range: 85% RH maximum
Construction:
Mating limit: mating limit or range of between the plug and the spring of pin jack shall be not regulated
Connection timing: the pin jack shall be permitted with connection timing whether shorting or not between the mutually separated terminals or springs of the pin jack, during the plug inserting and extracting
Creepage distance and spacing: creepage distance and spacing between mutually insulated parts shall be 0.3mm minimum, these distance, and spacing shall be maintained with or without the gauge plug inserted
Electrical characteristics:
Rated voltage/rated current: DC 342A
Insulation resistance: 100MΩ minimum
Contact resistance: 30mΩ maximum
Mechanical characteristics:
Operating force:
Insertion force: 29.4N (3kgf)
Withdrawal force: 0.98 to 29.4N maximum (0.1 to 3.0kgf)
Terminal strength/loosen strength of contact/strength of tapping part: without cracks or excessive looseness to the terminal, but deformation of terminal is authorized characteristics shall be satisfied
Endurance characteristics:
Operating endurance: electrical and mechanical characteristics shall be satisfied